Infinity HD250 External VR Model
Model: INFHD250HNC
Temperature controlled continuous flow gas hot water system for external applications. Factory preset to 55 °C.
Hot water capacity
2.4 to 37 litres per minute.
Energy efficiency
80%
| Colour: | Silver |
| Input: | 250 MJ/h or 69 kW |
| Output: | 55.2 kW |
| Efficiency: | 80% |
| Energy Star Rating | 5.3stars |
| Capacity |
Hot water capacity: 2.4 to 37 litres per minute Nominal water capacity: 32 litres per minute at a 25 °C rise (1920 L/h) |
| Connections |
Hot water oulet: R¾ (20 mm) Cold water inlet: R¾ (20 mm) Gas supply: R¾ (20 mm) |
| Exhaust System | Forced flue |
| Ignition System | Direct electronic ignition |
| Injector Size (mm) | NG: 1.00, 1.65 LPG: 0.75, 1.15 |
| Line Pressure (min.) | NG: 1.13 kPa, LPG:2.75 kPa |
| Line Pressure (max.) |
3.5 kPa (maximum standing pressure under abnormal intermittent conditions is 5.0 kPa). In the case of commercial metering (i.e. 35-37 kPa coming in), there may be a requirement to regulate the incoming line pressure down. |
| Power Consumption | Normal: 72 W, Standby: 2 W, Automatic Frost Protection: 116 W |
| Pressure Relief | Valve opens at 2060 kPa, valve closes at 1470 kPa |
| Noise Level | 49 dB(A) |
| Safety Devices | Flame failure, boil-dry protection, overheat protection (OHS), fusible link, pressure relief valve, combustion fan rpm check |
| Water Supply |
Nominal operating pressure: 200-1000 kPa Minimum water flow: 2.4 litres per minute |
| Weight | 29 kg |
| Compliance |
ESS Supplier Declaration of Compliance: • Declaration Number: 10996200911 • Certifcate Number: E1061/5498 |
- Commercial and domestic external applications
- Applications requiring higher hot water temperatures, can be set up to 95 °C
- Mains and low pressure systems
- Hard or acidic water will need to be treated in order to use this product.
Gas type
Available for Natural Gas or LPG. Specify gas type at time of purchase.
The following diagram has been provided to assist you in determining where (and if) an external continuous flow water heater can be positioned. If in doubt, prior to purchase, consult a licensed gasfitter. They will have access to 'Clearances Required for Flue Terminals' from the NZ Gas Installation standards (NZS 5261 2003).


| A | Width | 470 |
| B | Depth | 244 |
| C | Height - unit | 600 |
| D | Height including brackets | 644 |
| E | Hot water outlet from wall | 115 |
| F | Hot water outlet from centre | 61 |
| G | Cold water inlet from wall | 99 |
| H | Cold water inlet from centre | 52 |
| I | Gas connection from wall | 61 |
| J | Gas connection from centre | 110 |
| K | Condensate outlet from wall | • |
| L | Condensate outlet from centre | • |
| M |
Gas: Length of gas connection (from base) Cold: Length of cold water inlet (from base) Hot: Length of hot water outlet (from base) |
41 51 42 |
| Downloads | |
| Operation Manual | |
| Manifolding | |
| Servicing Schedule | |
| Installation Manual | |