A new generation of continuous flow water heater
Temperature controlled continuous flow gas hot water system for internal applications. Factory preset to 55 °C.

  • High efficiency (95%)
  • Lower gas emissions (due to a secondary heat exchanger)
  • Subsequent savings (water is preheated so doesn't use as much energy)
Colour: Gunmetal Grey
Input: 211 MJ/h or 58.6 kW
Output: 200 MJ/h or 55.6 kW
Efficiency: 95%
Energy Star Rating: 6.0 stars
REU Number: REU-KM3237FFUD-ZK


 

Capacity Hot water capacity: 1.5-37 litres per minute
Nominal water capacity: 32 litres per minute at a 25 ° rise (1920 L/h)
Connections Hot water outlet: R¾ (20 mm)
Cold water inlet: R¾ (20 mm)
Gas supply: R¾ (20 mm)
Condensate: R½ (15 mm)
Exhaust System Forced flue (balanced flued, room sealed fan assisted appliance)
Ignition System Direct electronic ignition
Injector Size NG: 1.15, 1.9, 1.8*
LPG: 0.75, 1.15, 1.1*
* only one point
Line Pressure (min.) NG: 1.13 kPa, LPG: 2.75 kPa
Line Pressure (max.) 3.5 kPa (maximum standing pressure under abnormal intermittent conditions is 5.0 kPa).
In the case of commercial metering (i.e. 35-37 kPa coming in), there may be a requirement to regulate the incoming line pressure down.
Power Consumption  Normal: LPG - 92 W, NG - 72 W
Automatic frost protection: 218 W
Standby: 2.4 W
Noise Level 50 dB(A)
NOx af < 60 ppm
Safety Devices Flame failure, boil-dry protection, overheat protection (OHS), fusible link, pressure relief valve, combustion fan rpm check
Water Supply Nominal operating pressure: 240-1000 kPa
Minimum water flow: 1.5 litres per minute
Weight 32 kg
Market Release July 2011
Compliance ESS: Supplier Declaration of Compliance
• Declaration Number: 

Suitable for

  • Commercial and domestic internal applications
  • Mains and low pressure systems

Hard or acidic water will need to be treated in order to use this product.

Gas type
Available for Natural Gas or LPG. Specify gas type at time of purchase.

   

product large image

 


All dimensions are in mm  
A Width 470
B Depth 257~307
C Height - unit 654
D Height - including brackets 721.6
E Hot water outlet from wall 100~150
F Hot water outlet from centre 100
G Cold water inelt from wall 64.6~114.6
H Cold water inlet from centre 27.7
I Gas connection from wall 89~139
J Gas connection from centre 103.2
K Condensate outlet from wall 122.6
L Condensate outlet from centre 195
M Gas: Length of gas connection (from base)
Cold: Length of cold water inlet (from base)
Hot: Length of hot water outlet (from base)
Condensate: Connection length (from base)
40.2
50.2
41.2
22.4

 